Is your family safe from electrocution?
Switchboard Safety
Each year Australians are killed in homes where electrical accidents could have been prevented. Even more are hospitalised with serious electrical injuries and burns. Many of these could have been prevented if safety switches had been installed in their house.
Preventable accidents with tragic consequences:
- a child inserting an implement into a toaster
- a handyman drilling into a live cable inside a wall
- stormwater leaking through a roof and into lights and appliances
Avoid tragedy and have a safety switch installed in your home
Master Electricians Australia is committed to helping home owners stay safe. A 10-point visual safety check of your home’s switchboard is now available. Unsafe switchboards can lead to fire, electric shock and potentially death. Your Master Electrician will discuss with you any electrical safety issues requiring urgent attention and things you might like to consider for the future.
If you have engaged a Master Electrician to undertake work for you, the 10-point visual safety check can be completed whilst on-site, no additional cost. If you require an electrician to come to your home to only undertake the safety check there will be a charge. Your electrician will discuss this with you prior to attending your home.
From January 2019, safety switches became mandatory on all circuits in new homes. They are designed to cut the power to an electrical circuit in the event of an electric shock. Safety switches on all circuits in the switchboard will increase the overall safety of the home.
Types of home safety switches
Example of completed Switchboard Safety Check
Recently, we had a member complete a 10-Point Switchboard Safety Check on a customer. The results are as follows.


(left – Vermin and Asbestos, centre – Rewireable fuses, right – Hot joints)
Score: 5/10
The installation failed on the following areas:
- Point 2 – Switchboard is free of vermin – evidence of vermin activity and cable entry hole unsealed.
- Point 3 – No asbestos visible – Metering panel made of Lebah.
- Point 4 – Main Earth in sound condition – No main earth stake only connection water pipe lead in (copper) appropriate to standard of the day. MEN connection intact and in good condition.
- Point 5 – No rewireable fuses – Original installation circuits still protected by fuses. Stove, Light, 2*Power & Hot water.
- Point 8 – Safety Switches – other circuits. RCD protection not on Stove, Hot Water and 1 * Air/Con.
Important notes:
- Urgent Action – Hot joints observed on line side of Main Switch and Stove fuse.
- Other Action – Recommended switchboard upgrade to address items above.
Case Studies
Terms and Conditions
This Safety Check has only involved a visual inspection of the equipment referred to on this document as it was at the time of inspection. Your Master Electrician cannot be held liable for any change in condition of that equipment, any loss or damage, including for consequential loss, arising from any defect or condition not noted on this document as seen by the Master Electrician nor for any failure to inspect, identify or advise you of any defect or failure other than those specifically noted on this document including liability arising from inaccessibility, oversight or negligence. This Safety Check is provided for your personal use only and may not be provided to any third party and any liability to any third party to whom it is provided, is specifically excluded including for negligence.